CIMENTART MICROCEMENT

WE ARE EXPERTS IN MICROCEMENT

We are present on five continents, with branches, representatives and works carried out in more than 35 countries today. For any type of consultation (microcement applications,
training, construction estimates, etc.), please do not hesitate to contact us

WORKING SYSTEM

TRADITIONAL MICROCEMENT WORKING SYSTEM

Tools required for application

  • Protective tape
  • Scissors or cutter
  • Sander
  • 40-grit sandpaper
  • 180-grit sandpaper
  • Spatula. Plastic trowel
  • Microfibre roller
  • Paint tray
  • Electric mixer
  • Vacuum cleaner
  • Measuring cup or digital scale

Required CimentArt products

  • CimentArt PLUS or STD Primer
  • CimentArt fibreglass mesh
  • KONCRET BASE flooring + MIX resin or Microcement BASE walls + MIX resin or Aqua BASE 100% waterproof
  • TRADITIONAL fine microcement + MIXING resin
  • STD Sealer
  • WB two-component polyurethane varnish (water-based) or HARD SB (solvent-based) CIMENTART (Comp A and Comp B).

Before starting

Check the surface where it will be applied and ensure that the surface is:

  • Straight
  • Firm and stable
  • Dry and free of moisture
  • Clean
  • Free of dust, grease, etc.

Preparation of surfaces

Any floor, uneven or cement wall, tiled walls, shower floors and, in general, any surface that is not completely smooth and perfectly flat needs to be levelled beforehand. To do this, we have three types of BASE microcement for levelling the surface:

  • KONCRET BASE (FLOORS): Can be applied to all indoor and outdoor floors, without exception. Two-component product. Mix 4 parts Koncret Base with 1 part Mixing Resin. Coverage: 1.25 kg/m² per 1 mm layer, with 2 layers always required.
  • Microcement BASE walls: Applied to walls that need levelling, both indoors and outdoors. Two-component product. Mix 3 parts Microcement BASE walls with 1 part Mixing Resin. Coverage: 1 kg/m² per 1 mm layer, with 2 layers always required.
  • Aqua BASE 100% waterproof: Applied to walls that need levelling and shower floors. Interior and exterior. Ready-to-use and 100% waterproof product. To achieve complete colour homogenisation, it is recommended to mix it with an electric mixer. Coverage: 1 kg/m² per 1 mm layer, with 2 layers always required.

Step-by-step application

Apply protective tape where necessary.

For application on completely smooth walls (i.e. walls without joints, imperfections or small rough patches, such as completely smooth, sanded and filled walls or painted plasterboard), only carry out steps 2, 3, 4 and 5 (skip step 1).

For application on floors, walls in poor condition or with tile joints, follow steps 1, 3, 4 and 5 (skip step 2).

1. Cement floors or walls, uneven or with tiles: 

Spread the CimentArt fibreglass MESH and apply a coat of CIMENTART PLUS PRIMER. 

Apply the first coat of any of our Microcemento BASE products.

  • Using a steel trowel at a 45° angle, apply a maximum thickness of 0.7 to 1 mm (the thickness is determined by the grain of the mixture and the pressure applied during application).
  • Finish the first layer, leaving it as smooth as possible and without irregularities.
  • Remove the protective tape before the Microcement BASE hardens.
  • Allow the first layer of Microcement BASE to dry completely.
  • Drying time is relative depending on humidity, temperature, ventilation, etc.
  • Remove any irregularities that may have remained after applying the first coat of Microcemento BASE with a spatula or 40-grit sandpaper.
  • Remove any dust created by sanding. You can also wipe with a damp cloth. 
  • Apply protective tape where necessary.
  • Apply the second coat of Microcemento BASE with a steel trowel, using an angle of 30°  , and applying a maximum thickness of 1 mm (the thickness is determined by the grain of the mixture and the pressure applied during application).
  • Finish this second coat, leaving it as smooth as possible and without any irregularities.
  • Tip: for both the first and second coats, you can spray lightly with water using a spray diffuser and smooth with the trowel to correct any irregularities. 
  • Remove the protective tape before the Microcement BASE hardens and allow the second layer of Microcement BASE to dry completely. 
  • Drying time is relative depending on humidity, temperature, ventilation, etc. 
  • Sand the second layer of Microcement thoroughly with 40-grit sandpaper, correcting any irregularities until the surface is completely smooth.
  • Remove the sanding dust by vacuuming. You can also wipe it with a damp cloth. 
  • Apply protective tape where necessary.

2. Completely smooth walls: 

Apply a coat of CimentArt PLUS or STD Primer.

Wash the roller and tray with water.

3. FINE TRADITIONAL Microcement 

The coverage of FINE TRADITIONAL Microcement is approximately 300 g/m² when applying the product in a 0.1 mm layer. Two layers must be applied, requiring a total of 600 g to cover 1 m². 

Tip: if you are applying CimentArt FINE Microcement to completely smooth walls, you may need to apply 4 coats to completely cover the surface.

  • Mix 750 grams of FINE TRADITIONAL Microcement with half a litre of CimentArt Mixing Resin.
  • Mix well with an electric mixer until there are no lumps. Leave to rest for 5 to 10 minutes (in winter; not necessary in summer).
  • Do not mix too much of this product, as it hardens faster than Microcement Base.

Application of the first coat of Microcemento FINE TRADICIONAL

  • Use our special trowel for FINE TRADITIONAL Microcement and apply with short, circular movements at an angle of 30°, applying a maximum thickness of 0.1 mm (the thickness is determined by the grain of the mixture, applying a certain amount of pressure with the trowel).
  • Finish the first coat, leaving it as smooth as possible and without irregularities.
  • Remove the protective tape. Allow the first layer of Microcemento FINE TRADITIONAL to dry completely.
  • The drying time is relative depending on humidity, temperature, ventilation, etc.
  • Sand the first layer of Microcemento FINE TRADITIONAL with 180-grit sandpaper, correcting any irregularities.
  • Remove the dust created by sanding with a vacuum cleaner.
  • Tip: before applying the second coat in very hot environments, you can lightly spray the surface with water using a spray bottle. This will help with the application.
  • Apply protective tape where necessary.

Apply a second coat of Microcemento FINE TRADITIONAL following the same procedure as for the first coat.

  • Using the plastic trowel, apply in short, circular movements at an angle of 30°, applying a maximum thickness of 0.1 mm (the thickness is determined by the grain of the mixture, applying a certain amount of pressure with the trowel).
  • Finish the second coat, leaving it as smooth as possible and without any irregularities.
  • Tip: to ensure that no joints are visible, the final layer of FINE TRADITIONAL Microcement should be applied continuously without stopping.
  • Remove the protective tape and allow the second layer of Microcemento FINE TRADITIONAL to dry completely.
  • Drying time depends on humidity, temperature, ventilation, etc.
  • Sand the second coat of Microcemento FINE TRADITIONAL with 180-grit sandpaper, correcting any irregularities.
  • Remove the dust created by sanding with a vacuum cleaner. Never use a damp cloth at this stage.

4. STD Sealer

  • Apply protective tape where necessary.
  • Pour the STD Sealer into a tray and apply an even coat with a short-haired roller or microfibre roller.
  • The coverage of STD Sealer is 100 g/m². To cover 10 m², you will need 1 kg.

Wash the roller and tray with soap and water.

  • Allow the Sealer to dry. Drying time depends on humidity, temperature, ventilation, etc. It usually dries fairly quickly.

5. CimentArt Two-Component Polyurethane Varnish

WB water-based 2-component varnish

Recommended for: interior and exterior application on all walls and ceilings and on floors with moderate foot traffic.

Preparation:

  • Mix 5 parts of Component A of the 2-component water-based varnish with 1 part of Component B.
  • To make 1 kg of varnish with the 2 components, you will need 840 g of Component A and 160 g of Component B.
  • The approximate coverage is 50 g/m², applying a thin layer of 0.1 mm. It is always necessary to apply 2 coats. To cover 10 m² with 2 coats, you will need approximately 1 kg of the mixture.

HARD SB solvent-based 2-component varnish

Recommended for: indoor and outdoor application on floors with heavy foot traffic.

Preparation:

  • Mix 2 parts of Component A of the 2-component solvent-based varnish with 1 part of Component B.
  • To make 1 kg of solvent-based 2-component varnish with the 2 components, you will need 666 g of Component A and 333 g of Component B.
  • The approximate coverage is 100 g/m², applying a thin layer of 0.1 mm. It is always necessary to apply 2 coats. To cover 10 m² with one coat, you will need approximately 1 kg of the mixture.
  • Apply a first coat of varnish 0.1 mm thick with a microfiber roller or spray gun (combing the surface well if applying with a roller) and leave to dry for at least twelve hours.
  • Apply a second coat with a microfiber roller or spray gun, exactly the same as the first coat.
  • You can apply an extra third coat for added protection, especially in areas that come into direct contact with water, such as showers, outdoor terraces, etc.
  • Do not forget to wash the roller and tray with water or solvent, depending on the type of varnish used.

Important

  • You can apply FINE TRADITIONAL Microcement to any surface, except for surfaces with capillary moisture, swimming pools, car parks and factories with heavy machinery traffic.
  • We do not recommend applying FINE TRADITIONAL Microcement to shower floors or outdoor terraces, as it has a very smooth finish and can be slippery when in contact with water.
  • Never apply layers of Microcement BASE with a thickness greater than 1 mm.
  • Never apply layers of Microcemento FINE TRADITIONAL with a thickness greater than 0.1 mm.
  • Microcemento FINE Traditional, iCem, Oxide or Microstucco CIMENTART should not be used on shower floors or outdoor terraces (horizontal surfaces that receive large amounts of water). For these types of surfaces, we recommend using the AQUA range, which is ready to use and 100% waterproof.
  • In high-traffic areas such as shops, offices or shopping centres, etc., we recommend applying a third coat of HARD SB solvent-based 2-component varnish.
  • Always apply any of our CimentArt 2-component varnishes in thin layers of 0.1 mm.
  • Ensure that the entire microcement surface is perfectly covered with any of our 2-component varnishes.
  • We recommend finishing any floor with any of our CimentArt 2-component varnishes with a GLOSS or SATIN finish.
  • We do not recommend finishing Microcement with a porous or rustic finish and/or light colours on floors, as they will be more difficult to clean.

For technical advice, please write to us at: info@grupocimentart.com
Last updated: August 2025

TRADITIONAL MICROCEMENT
Nº: 25/32303351 UNE-EN 13813:2014 & UNE-EN 15824:2017
Two-component decorative coating for preparation and finishing of interior walls, ceilings and floors (except showers) and exterior walls. Can be applied over cement, plaster, drywall, tiles, and gypsum.
Fire reaction: A1 Class
Adherence: 0,8 N/mm2
Impact resistance: 14,7 n/mm2
Abrasion resistence: 40 μm
Liquid water permeability: 0,02 Kg/m2 h05
Direct traction adhesion: 0,6 MPa
Water vapor permeability: 0,005 g/h
Hazardous substances: See Safety Data Sheet